Ceph入门到精通- storcli安装

storcli 是LSI公司官方提供的Raid卡管理工具,storcli已经基本代替了megacli,是一款比较简单易用的小工具。将命令写成一个个的小脚本,会将使用变得更方便。

安装简单,Windows系统下解压出来以后可以直接运行。

Linux系统默认位置在 /opt/MegaRAID/storcli下面,安装完成后可以按照个人使用习惯拷贝到/usr/bin和/usr/sbin下,也可以直接到安装目录运行。

下载地址

Broadcom官网:https://www.broadcom.com/site-search?q=storcli

百度云盘:

链接:https://pan.baidu.com/s/1c_PBmz5UoWSjT3h6cZG3Vw

提取码:long

安装步骤

[root@localhost~]#unzip 007.1715.0000.0000_Unified_StorCLI-PUL.zip
[root@localhost~]#cd Unified_storcli_all_os/
[root@localhost~]#cd Linuxrpm -ivhstorcli-007.1705.0000.0000-1.noarch.rpm
[root@localhost~]# rpm -ivh storcli-007.1704.0000.0000-1.noarch.rpm
warning:storcli-007.1704.0000.0000-1.noarch.rpm: Header V3 RSA/SHA256 Signature,
key ID cb529165: NOKEY Preparing... ################################# [100%] Updating /installing... 1:storcli-007.1704.0000.0000-1 ###############################[100%]
查看安装是否成功
[root@localhost storcli]# ls /opt/MegaRAID/storcli/
install.log storcli64 storcli.log
拷贝到可执行文件目录
cp/opt/MegaRAID/storcli/storcli64 /usr/bin/
cp/opt/MegaRAID/storcli/storcli64 /usr/sbin/

获取帮助

storcli64 -h

 

storcli64 show all

1.对更换完的硬盘进行划分raid0,并开启ssdcache功能

storcli64 /c1 add vd r0 size=all divers = 18:10 cached(storcli64 /c1 add vd r0 drives=18:10,storcli64 /c1/v9 set iopolicy=Cached)

storcli64 /c1/v9  set ssdcaching=on

2.确认ok后,在对应的存储节点进行盘的检查。

3.通知停响应节点监控

4.osd的添加,执行相应脚本内容。(具体情况)

parted_new_disk.sh

add_osd.sh

 

Linux使用storcli工具查看服务器硬盘和raid组信息

1、简介

MegaCli 是LSI公司官方提供的SCSI卡管理工具,由于LSI被收购变成了现在的Broadcom,所以现在想下载MegaCli,

需要去Broadcom官网查找Legacy产品支持,搜索MegaRAID即可。

现在官方有storcli,storcli已经基本代替了megacli,整合了LSI和3ware所有产品。

安装方面比较简单,megacli还要Lib_Utils的支持,而storcli只用一个rpm包就可以下载,

去Broadcom官网去找就行了:Search Results

storcli支持json格式输出,信息解析更加方便。

我个人推荐使用这个软件,因为megacli 工具需要安装额外的软件包,有些服务器客户不允许安装其他的软件包,所以比较麻烦。

这个工具直接安装了之后就可以用。

 

1.1服务器信息:

 

1.2系统信息:

[root@localhost storcli]# cat /etc/redhat-release

Red Hat Enterprise Linux Server release 6.4 (Santiago)

1.3 安装storcli

rpm -ivh  storcli-1.03.11-1.noarch.rpm

目录: /opt/Mega/storcli

注意版本问题

我这台服务器是DELL  R720xd,2012年上线的,所以我用的是storcli.1.03.11版本。

我用的新版本安装之后,执行命令没有输出,所以这一点需要注意。

1.4一些参数定义:

/cx = Controller ID

/vx = Virtual Drive Number.

/ex = Enclosure ID

/sx = Slot ID

1.5为了管理方便,建立软连接

ln -s /opt/MegaRAID/storcli/storcli64 /bin/storcli

ln -s /opt/MegaRAID/storcli/storcli64    /sbin/storcli

如果不想建立软连接,就在/opt/MegaRAID/storcli 目录下 执行./storcli64 指令

2、查看当前设备raid控制器相关信息

[root@localhost storcli]# ./storcli64 show all    可以看到只有一个控制器

Status Code = 0

Status = Success

Description = None

 

Number of Controllers = 1

Host Name = localhost.localdomain

Operating System  = Linux2.6.32-358.el6.x86_64

System Overview :

===============

------------------------------------------------------------

Ctl Model Ports PDs DGs DNOpt VDs VNOpt BBU sPR DS EHS ASOs

------------------------------------------------------------

  0 Mini      8  14   3     0   3     0 Opt On  3  N      0      【只看到一个控制器】

------------------------------------------------------------

Ctl=Controller Index|DGs=Drive groups|VDs=Virtual drives|Fld=Failed

PDs=Physical drives|DNOpt=DG NotOptimal|VNOpt=VD NotOptimal|Opt=Optimal

Msng=Missing|Dgd=Degraded|NdAtn=Need Attention|Unkwn=Unknown

sPR=Scheduled Patrol Read|DS=DimmerSwitch|EHS=Emergency Hot Spare

Y=Yes|N=No|ASOs=Advanced Software Options|BBU=Battery backup unit

ASO :

===

----

Ctl

----

  0

----

Cl=Cluster|MD=Max Disks|WC=Wide Cache|SS=Safe Store|FP=Fast Path|Re=Recovery

CR=CacheCade(Read)|RF=Reduced Feature Set|CO=Cache Offload

CW=CacheCade(Read/Write)|X=Not Available/Not Installed|U=Unlimited|T=Trial

3、查看控制器c0的相关信息

[root@localhost storcli]# ./storcli64  /c0 show

Controller = 0

Status = Success

Description = None

Product Name = PERC H710P Mini【控制器型号】

Serial Number = 26300UP

SAS Address =  5d4ae520a6bcbc00

Mfg. Date = 06/04/12

System Time = 05/22/2019 16:22:28

Controller Time = 05/22/2019 08:22:28

FW Package Build = 21.0.2-0001

BIOS Version = 5.30.00_4.12.05.00_0x05110000

FW Version = 3.130.05-1587

Driver Name = megaraid_sas

Driver Version = 06.504.01.00-rh1

Controller Bus Type = N/A

PCI Slot = N/A

PCI Bus Number = 2

PCI Device Number = 0

PCI Function Number = 0

Drive Groups = 3

TOPOLOGY :

========

--------------------------------------------------------------------------

DG Arr Row EID:Slot DID Type  State BT       Size PDC  PI SED DS3  FSpace

--------------------------------------------------------------------------

0 -   -   -        -   RAID1 Optl  N  278.875 GB dflt N  N   dflt N      

0 0   -   -        -   RAID1 Optl  N  278.875 GB dflt N  N   dflt N      

0 0   0   32:24    24  DRIVE Onln  N  278.875 GB dflt N  N   dflt -      

0 0   1   32:25    25  DRIVE Onln  N  278.875 GB dflt N  N   dflt -      

1 -   -   -        -   RAID5 Optl  N    4.089 TB dflt N  N   dflt N      

1 0   -   -        -   RAID5 Optl  N    4.089 TB dflt N  N   dflt N      

1 0   0   32:0     0   DRIVE Onln  N   837.75 GB dflt N  N   dflt -      

1 0   1   32:1     1   DRIVE Onln  N   837.75 GB dflt N  N   dflt -      

1 0   2   32:2     2   DRIVE Onln  N   837.75 GB dflt N  N   dflt -      

1 0   3   32:3     3   DRIVE Onln  N   837.75 GB dflt N  N   dflt -      

1 0   4   32:4     4   DRIVE Onln  N   837.75 GB dflt N  N   dflt -      

1 0   5   32:5     5   DRIVE Onln  N   837.75 GB dflt N  N   dflt -      

2 -   -   -        -   RAID5 Optl  N    4.089 TB dflt N  N   dflt N      

2 0   -   -        -   RAID5 Optl  N    4.089 TB dflt N  N   dflt N      

2 0   0   32:6     6   DRIVE Onln  N   837.75 GB dflt N  N   dflt -      

2 0   1   32:7     7   DRIVE Onln  N   837.75 GB dflt N  N   dflt -      

2 0   2   32:8     8   DRIVE Onln  N   837.75 GB dflt N  N   dflt -      

2 0   3   32:9     9   DRIVE Onln  N   837.75 GB dflt N  N   dflt -      

2 0   4   32:10    10  DRIVE Onln  N   837.75 GB dflt N  N   dflt -      

2 0   5   32:11    11  DRIVE Onln  N   837.75 GB dflt N  N   dflt -      【可以看到服务器有几个RAID,每个RAID的级别和成员盘】

--------------------------------------------------------------------------

DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID

DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded

Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active

PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign

DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present

Virtual Drives = 3【服务器有三个RAID,两个RAID5一个RAID1】

VD LIST :

=======

---------------------------------------------------------------

DG/VD TYPE  State Access Consist Cache Cac sCC       Size Name

---------------------------------------------------------------

0/0   RAID1 Optl  RW     Yes     RaWBD R   OFF 278.875 GB      

1/1   RAID5 Optl  RW     Yes     RaWBD R   OFF   4.089 TB      

2/2   RAID5 Optl  RW     Yes     RaWBD R   OFF   4.089 TB      

---------------------------------------------------------------

Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded

Optl=Optimal|RO=Read Only|RW=Read Write|B=Blocked|Consist=Consistent|

Ra=Read Ahead Adaptive|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|

AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled

Check Consistency

 

Physical Drives = 14【十四个物理磁盘】

PD LIST :

=======

-------------------------------------------------------------------------

EID:Slt DID State DG       Size Intf Med SED PI SeSz Model            Sp

-------------------------------------------------------------------------

32:0      0 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:1      1 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:2      2 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:3      3 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:4      4 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:5      5 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:6      6 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:7      7 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:8      8 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:9      9 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:10    10 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:11    11 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:24    24 Onln   0 278.875 GB SAS  HDD N   N  512B ST9300603SS      U  

32:25    25 Onln   0 278.875 GB SAS  HDD N   N  512B ST9300605SS      U  

-------------------------------------------------------------------------

EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup

DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare

UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface

Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info

SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign

BBU_Info :

========

------------------------------------------------------------

Model State   RetentionTime Temp Mode MfgDate    Next Learn

------------------------------------------------------------

BBU   Optimal 0 hour(s)     30C  0    2011/07/18 None       

------------------------------------------------------------

4、获取enclosure信息

硬盘大多是附在enclosure上不是直接附在controller上。

显示所有的enclosure信息,但是系统中只有一个enclosure ,EID:32.

[root@localhost storcli]# ./storcli64 /c0/eall show   

Controller = 0

Status = Success

Description = None

Properties :

==========

-----------------------------------------------------------------------------

EID State Slots PD PS Fans TSs Alms SIM Port#       ProdID    VendorSpecific

-----------------------------------------------------------------------------

32 OK       26 14  0    0   0    0   0 Unavailable BP12G+EXP                

-----------------------------------------------------------------------------

EID-Enclosure Device ID |PD-Physical drive count |PS-Power Supply count|

TSs-Temperature sensor count |Alms-Alarm count |SIM-SIM Count

获取单个enclosure  ,e32详细信息

[root@localhost storcli]# ./storcli64 /c0/e32 show all

Controller = 0

Status = Success

Description = None

Enclosure /c0/e32  :

==================

Information :

===========

Device ID = 32

Position = 1

Connector Name = Unavailable

Enclosure Type = SES

Status = OK

FRU Part Number = N/A

Enclosure Serial Number = N/A

ESM Serial Number = N/A

Enclosure Zoning Mode = N/A

Partner Device ID = 65535

Inquiry Data :

============

Vendor Identification = DP

Product Identification = BP12G+EXP

Product Revision Level = 1.07

Properties :

==========

-----------------------------------------------------------------------------

EID State Slots PD PS Fans TSs Alms SIM Port#       ProdID    VendorSpecific

-----------------------------------------------------------------------------

32 OK       26 14  0    0   0    0   0 Unavailable BP12G+EXP                

-----------------------------------------------------------------------------

EID-Enclosure Device ID |PD-Physical drive count |PS-Power Supply count|

TSs-Temperature sensor count |Alms-Alarm count |SIM-SIM Count

5、显示物理磁盘信息

语法:storcli64  /cx/eall/sall show  显示所有物理磁盘信息

[root@localhost storcli]# ./storcli64 /c0/e32/sall   show 【显示e32上的所有物理硬盘】 

[root@localhost storcli]# ./storcli64 /c0/eall/sall show【显示所有enclosure下的所有物理硬盘

Controller = 0

Status = Success

Description = Show Drive Information Succeeded.

Drive Information :

=================

-------------------------------------------------------------------------

EID:Slt DID State DG       Size Intf Med SED PI SeSz Model            Sp

-------------------------------------------------------------------------

32:0      0 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:1      1 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:2      2 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:3      3 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:4      4 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:5      5 Onln   1  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:6      6 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:7      7 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:8      8 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:9      9 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:10    10 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:11    11 Onln   2  837.75 GB SAS  HDD N   N  512B WD9001BKHG       U  

32:24    24 Onln   0 278.875 GB SAS  HDD N   N  512B ST9300603SS      U  

32:25    25 Onln   0 278.875 GB SAS  HDD N   N  512B ST9300605SS      U  

-------------------------------------------------------------------------

EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup

DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare【表示有热备盘,DHS专有热备,GHS全局热备】

UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface

Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info

SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign

从上面信息,可以看出:

  • 只有一个控制器,id 为 0

  • EID,Enclosure Device ID :32

  • Slot Number,能看到 0,1,2,3,4,5,6,7,8,9,10,11,24,25

  • DG:disk group,0,1,2

  • size:容量,磁盘容量

  • intf:接口,SAS

  • Med:介质,ssd 或 hdd

6、查看raid组详细信息

查看系统里面有几个raid组:

[root@localhost storcli]# ./storcli64 /c0/vall  show 【查看c0控制下的所有RAID信息】

Controller = 0

Status = Success

Description = None

Virtual Drives :

==============

---------------------------------------------------------------

DG/VD TYPE  State Access Consist Cache Cac sCC       Size Name

---------------------------------------------------------------

0/  RAID1 Optl  RW     Yes     RaWBD R   OFF 278.875 GB      

1/  RAID5 Optl  RW     Yes     RaWBD R   OFF   4.089 TB      

2/2   RAID5 Optl  RW     Yes     RaWBD R   OFF   4.089 TB      【显示系统有三个raid组】

---------------------------------------------------------------

Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded

Optl=Optimal|RO=Read Only|RW=Read Write|B=Blocked|Consist=Consistent|

Ra=Read Ahead Adaptive|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|

AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled

Check Consistency

查看V0  (虚拟磁盘0) raid的详细信息

[root@localhost storcli]# ./storcli64 /c0/v0 show all

Controller = 0

Status = Success

Description = None

/c0/v0 :

======

---------------------------------------------------------------

DG/VD TYPE  State Access Consist Cache Cac sCC       Size Name

---------------------------------------------------------------

0/0   RAID1 Optl  RW     Yes     RaWBD R   OFF 278.875 GB      【V0为RAID1】

---------------------------------------------------------------

Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded

Optl=Optimal|RO=Read Only|RW=Read Write|B=Blocked|Consist=Consistent|

Ra=Read Ahead Adaptive|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|

AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled

Check Consistency

PDs for VD 0 :

============

-------------------------------------------------------------------------

EID:Slt DID State DG       Size Intf Med SED PI SeSz Model            Sp

-------------------------------------------------------------------------

32:24    24 Onln   0 278.875 GB SAS  HDD N   N  512B ST9300603SS      U  

32:25    25 Onln   0 278.875 GB SAS  HDD N   N  512B ST9300605SS      U  【可以看到24号和25号盘组成了raid1

-------------------------------------------------------------------------

EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup

DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare

UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface

Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info

SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign

VD0 Properties :

==============

Strip Size = 64 KB

Span Depth = 1

Number of Drives Per Span = 2

Disk Cache Policy = Disk's Default

Encryption = None

Data Protection = None

Active Operations = None

Exposed to OS = Yes

Creation Date = 05-09-2012

Creation Time = 01:38:23 PM

Emulation type = None

7、磁盘状态设置

storcli64    /cx/ex/sx    set    good/offline/online/missing  设置某块磁盘的状态

good        空闲

online/offline       成员盘上下线

missing            设置磁盘为missing状态

磁盘热备

storcli64 /cx/ex/sx add hotsparedrive dgs=x  设置模块磁盘为diskgroup x 的热备盘

storcli64 /cx/ex/sx add hotsparedrive           设置全局热备

storcli64 /cx/ex/sx delete hotsparedrive

磁盘rebuild

storcli64 /cx/ex/sx show rebuild  查看rebild

storcli64 /cx/ex/sx start rebuild

storcli64 /cx/ex/sx stop rebuild

磁盘点灯

storcli64 /cx/ex/sx start locate

storcli64 /cx/ex/sx stop locate

磁盘擦除

快速擦除:

storcli64 /cx/ex/sx set good

storcli64 /cx/fall del|delete [securityKey = xxx]

完全擦除:

storcli /cx[/ex]/sx secureerase [force]

storcli /cx[/ex]/sx start erase [simple| normal| thorough | standard| threepass | crypto]

storcli /cx[/ex]/sx stop erase

storcli /cx[/ex]/sx show erase

8、获取rebuild速率

[root@localhost storcli]# ./storcli64  /c0 show rebuildrate

Controller = 0

Status = Success

Description = None

Controller Properties :

=====================

------------------

Ctrl_Prop   Value

------------------

Rebuildrate 30%   

------------------

storcli64   /c0  set  rebuildrate=60  设置rebuild速率

9、清除缓存

清除raid卡,物理磁盘cache

storcli64   /c0    flushcache

 

本文来自互联网用户投稿,该文观点仅代表作者本人,不代表本站立场。本站仅提供信息存储空间服务,不拥有所有权,不承担相关法律责任。如若转载,请注明出处:/a/14786.html

如若内容造成侵权/违法违规/事实不符,请联系我们进行投诉反馈qq邮箱809451989@qq.com,一经查实,立即删除!

相关文章

Android程序员向音视频进阶,有前景吗

随着移动互联网的普及和发展,Android开发成为了很多人的就业选择,希望在这个行业能获得自己的一席之地。然而,随着时间的推移,越来越多的人进入到了Android开发行业,就导致目前Android开发的工作越来越难找&#xff0c…

7.Shuffle详解

1.分区规则 ps."&"指的是按位与运算,可以强制转换为正数 ps."%",假设reduceTask的个数为3,则余数为0,1,2正好指代了三个分区 以上代码的含义就是对key的hash值强制取正之后,对reduce的个数取…

大数据技术之Kafka集成

一、集成Flume 1.1 Flume生产者 (1)启动Kafka集群 zkServer.sh startnohup kafka-server-start.sh /opt/soft/kafka212/config/server.properties & (2)启动Kafka消费者 kafka-console-consumer.sh --bootstrap-server 192…

动态内存管理

文章目录 1.动态内存函数1.1free1.2malloc1.3calloc1.4realloc 2.动态内存错误2.1解引用空指针--非法访问内存2.2越界访问动态空间2.3free释放非动态空间2.4free释放部分动态空间2.5free多次释放动态空间2.6未释放动态内存 3.动态内存题目3.1形参不影响实参3.2地址返回&#xf…

APP渗透—查脱壳、反编译、重打包签名

APP渗透—查脱壳、反编译、重打包签名 1. 前言1.1. 其它 2. 安装工具2.1. 下载jadx工具2.1.1. 下载链接2.1.2. 执行文件 2.2. 下载apktool工具2.2.1. 下载链接2.2.2. 测试 2.3. 下载dex2jar工具2.3.1. 下载链接 3. 查壳脱壳3.1. 查壳3.1.1. 探探查壳3.1.2. 棋牌查壳 3.2. 脱壳3…

FVM初启,Filecoin生态爆发着力点在哪?

Filecoin 小高潮 2023年初,Filecoin发文分享了今年的三项重大变更,分别是FVM、数据计算和检索市场的更新,这些更新消息在发布后迅速吸引了市场的广泛关注。 特别是在3月14日,Filecoin正式推出了FVM,这一变革使得Filec…

多维时序 | MATLAB实现BO-CNN-GRU贝叶斯优化卷积门控循环单元多变量时间序列预测

多维时序 | MATLAB实现BO-CNN-GRU贝叶斯优化卷积门控循环单元多变量时间序列预测 目录 多维时序 | MATLAB实现BO-CNN-GRU贝叶斯优化卷积门控循环单元多变量时间序列预测效果一览基本介绍模型描述程序设计参考资料 效果一览 基本介绍 基于贝叶斯(bayes)优化卷积神经网络-门控循环…

python 基础语法

标准库 语言参考手册 abstract base class – 抽象基类 abc annotation – 标注 类型注解 argument – 函数参数 关键字参数 xxx / **{xxx: , xx: }位置参数 3, 5 / *(3, 5) 基础语法 使用严格缩进 代替 大括号{} 框定代码块 使用反斜杠 \ 将一行的语句分为多行显示 三引…

ENVI 国产高分2号(GF-2)卫星数据辐射定标 大气校正 影像融合

1.数据 高分2号卫星数据,包含: MSS-1\2多光谱数据,4m分辨率; Pan-1\2全色波段数据,0.8m分辨率。 2.处理软件 ENVI5.3 国产插件下载地址:ENVI App Store (geoscene.cn) 首先下载插件文件; …

【STL十四】函数对象(function object)_仿函数(functor)——lambda表达式

【STL十四】函数对象(function object)_仿函数(functor)——lambda表达式 一、函数对象(function object)二、函数对象优点三、分类四、头文件五、用户定义函数对象demo六、std::内建函数对象1、 算术运算函…

【分布式技术专题】「分布式技术架构」手把手教你如何开发一个属于自己的Redis延时队列的功能组件

手把手教你如何开发一个属于自己的延时队列的功能组件 前提介绍解决痛点延时队列组件的架构延时队列组件的初始化流程延时队列组件的整体核心类架构延时队列组件的整体核心类功能 延时队列的开发组件延迟队列的机制配置初始化类源码 - DelayedQueueConfigurationRedission客户端…

网络基础,InetAddress,Socket,TCP,UDP

概念:两台设备之间通过网络实现数据运输网络通信:将数据通过网络从一台设备传输到另一台设备java.net包下提供了一系列的类或接口,供程序员使用,完成网络通信网络:两台或多台设备通过一定物理设备连接起来构成了网络根…

文件和用户管理

Linux基础 提示:个人学习总结,仅供参考。 一、Linux系统部署 二、服务器初始化 三、文件和用户管理 四、用户的权限 提示:文档陆续更新整理 文件和用户管理 Linux基础一、Linux目录结构二、文件管理1.文件类型2.文件管理命令 三、用户管理…

为什么医疗保健需要MFT来帮助保护EHR文件传输

毫无疑问,医疗保健行业需要EHR技术来处理患者,设施,提供者等之间的敏感患者信息。但是,如果没有安全的MFT解决方案,您将无法安全地传输患者文件,从而使您的运营面临遭受数据泄露,尴尬&#xff0…

如何平衡倾斜摄影的三维模型轻量化数据文件大小和质量效果?

如何平衡倾斜摄影的三维模型轻量化数据文件大小和质量效果? 倾斜摄影超大场景的三维模型数据文件大小的具体范围取决于多种因素,如原始数据的复杂度、轻量化处理的方式和压缩算法等。一般而言,经过轻量化处理后,数据文件大小可以减…

c/c++:栈帧,传值,传址,实参传值给形参,传地址指针给形参

c/c:栈帧,传值,传址,实参传值给形参,传地址指针给形参 2022找工作是学历、能力和运气的超强结合体,遇到寒冬,大厂不招人,此时学会c的话, 我所知道的周边的会c的同学&…

WuxioLin 反锯齿算法(反走样算法,Xiaolin Wu Anti-aliasing algorithm) C# 代码实现

提示:文章写完后,目录可以自动生成,如何生成可参考右边的帮助文档 文章目录 前言一、锯齿和反锯齿二、Xiaolin Wu 算法代码1.C#完整代码如下2.举例和测试 总结 前言 笔者前几日自己写了个佳明手表表盘的的一个入门级App,模拟指针…

甘肃vr全景数字化展厅提高企业品牌认知度和销售效果

相比传统式展厅给观众们呈现的是静态的视觉体会,缺乏实时交互水平。而720VR全景虚拟展厅能够提供高度真实的展览体验,融合视、听、触等各种感官享受,带来颠覆的沉浸式体验。 即便社恐的你也能在虚拟现实的世界游刃有余,想看哪里点…

AD9208子卡设计资料: 2 路 2.6GSPS/3GSPS AD 采集、2 路 12.6G DA 回放、高性能时钟发生器HMC7044 -FMC 子卡模块

板卡概述 FMC123 是一款基于 FMC 标准规范,实现 2 路 14-bit、3GSPSADC 采集功能、2 路 16-bit 12.6GSPS 回放子卡模块。该模块遵循 VITA57.1 标准,可直接与 FPGA 载卡配合使用,板卡 ADC 器件采用 ADI 公司的 AD9208 芯片,&…

《中学科技》期刊简介及投稿邮箱

《中学科技》期刊简介及投稿邮箱 《中学科技》以传播科技知识、启迪智慧、培养才能为宗旨,提供电子技术、计算机、陆海空模型、数学、物理、化学、生物、天文等方面的科技活动资料,特别注意通过科学观察,实验和制作实践的途径,培…